Winkelwagen0artikelen

Overvoltage relay 4-pin – Mercedes W123 W116 R107

SKU: MB-1165450034-E-NB
High-quality, true-to-original 4-pole surge protection for early Mercedes models with ABS.

Protects the electronic ABS control equipment against harmful voltage spikes in the vehicle's electrical system.

Suitable for certain versions of the Mercedes R107, C107, W116, W123 and W126.

NB: Exclusively for the original first generation surge protection. Not interchangeable with later 4-pole and 5-pole versions.

Sale: per piece.

€ 61,71 incl. VAT (€ 51,00 excl. VAT)

15 in stock

0

Description

Overvoltage protection 4-pole Mercedes R107 C107 W116 W123 W126 – ABS

This 4-pole surge protection protects the electronic control equipment of early Mercedes models with ABS against harmful voltage spikes in the vehicle's electrical system.

This component was used in the first generation of Mercedes ABS systems. The surge protection helps limit voltage spikes, for example from the ignition or electrical system, thereby protecting the sensitive electronics of the ABS system.

High-quality, faithful reproduction

This new surge protection is designed as faithful reproduction of the original Mercedes part. The housing and electrical connection are matched to the original version.

This makes this part suitable for maintenance, repair, and restoration where preserving the original appearance is important.

Suitable for Mercedes models

R107 – SL Roadster

• 280 SL – early versions with ABS
• 350 SL – versions with suitable surge protection
• 380 SL – early versions with ABS
• 450 SL – early versions with ABS

C107 – SLC Coupé

• 280 SLC – versions with suitable surge protection
• 350 SLC – versions with suitable surge protection
• 380 SLC – early versions with ABS
• 450 SLC – early versions with ABS

W116 – S-Class Sedan

• 280 S – versions with suitable surge protection
• 280 SE – versions with ABS
• 280 SEL – versions with ABS
• 350 SE – versions with ABS
• 350 SEL – versions with ABS
• 450 SE – versions with ABS
• 450 SEL – versions with ABS
• 450 SEL 6.9 – versions with ABS

W123 – Sedan, Coupé and Station Wagon

• Early versions with ABS and the original 4-pole surge protection

W126 – S-Class Sedan

• 280 SE – early versions with ABS
• 280 SEL – early versions with ABS
• 380 SE – early versions with ABS
• 380 SEL – early versions with ABS
• Other early versions only if the original part number matches

Important: This surge protection is intended for the first generation, which was used until approximately August 1981. The exact application depends on the version, production date, and electrical installation.

Specifications and additional information
  1. Element: surge protection – surge protection relay – OVP
  2. Execution: first generation
  3. Number of connections: 4-pin
  4. Mercedes OEM number: A1165450034
  5. Housing: faithful reproduction
  6. Production: high-quality new reproduction
  7. Function: limiting harmful voltage spikes in the onboard network
  8. Application: protection of electronic ABS control equipment
  9. Assembly: replacement of the original version with the same part number and the same connection configuration
  10. Sale: per piece
Operation of the surge protection

The first generation Mercedes surge protection contains a protection diode and an internal fuse.

In the event of voltage spikes above the protection limit, the diode helps to dissipate the overvoltage. This protects the electronics of the ABS system against harmful voltage spikes.

NB: This first generation is technically constructed differently from the later surge relays. The component does not contain a traditional switching relay as in later versions.

Even a properly functioning surge protector cannot guarantee that all voltage spikes are completely suppressed.

Possible symptoms in case of a defect

A defective surge protector can cause the following symptoms, among others:

  1. The ABS warning light remains on.
  2. The ABS system is not working correctly.
  3. The electrical power supply to the ABS control unit is interrupted.
  4. The internal security has failed.

These symptoms can also have other causes. Therefore, first check the electrical system and the ABS system before replacing any parts.

Installation advice
  1. Check the original Mercedes part number before ordering.
  2. Compare the 4-pin connection and the terminal configuration with the old part.
  3. Switch off the ignition and disconnect the battery before working on the electrical system.
  4. Check the relay base and connections for corrosion, damage, and overheating.
  5. Install the surge protection exclusively in the designated connection.
  6. Check the operation of the ABS system after installation.
Important – not interchangeable with later versions

The first generation A1165450034 is not interchangeable with the later 4-pole or 5-pole surge relays.

Although the connections may look similar and the component sometimes physically fits into the relay base, the electrical connection configuration is different.

Installation of the wrong version can cause a short circuit and damage to the electrical installation.

Therefore, always check the original part number and consult the Mercedes workshop documentation in case of doubt.

A defective alternator, voltage regulator, or other fault in the vehicle's electrical system can cause voltage spikes. Replacing the surge protection does not resolve such underlying problems.

Always check before purchase and installation whether the part is suitable and equivalent based on photos, description, and specifications; installed or used parts cannot be returned.

Additional information

Weight0,034 kg
Dimensions6 × 4 × 4 cm